Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Perit Dial Int ; 43(3): 231-240, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36855928

RESUMEN

INTRODUCTION: Peritoneal dialysis (PD) catheter complications reduce quality of life and increase risks for hospitalizations, for unplanned transitions to haemodialysis and for death. Patient PD catheter management is crucial for safe, sustained PD. Patient perspectives on strategies for living with PD and using a PD catheter may inform efforts to reduce PD catheter complications, increase individual patient PD modality persistence, and thus increase overall home dialysis prevalence. METHODS: We interviewed 32 adult PD patients in Nashville, Tennessee. Qualitative analyses included (1) isolation of themes, (2) development of a coding system and (3) creation of a conceptual framework using an inductive-deductive approach. RESULTS: Challenges identified by patients as important included drain pain, difficulty eating and sleeping, and fear of peritonitis. Coping strategies included repositioning while draining, adjusting eating patterns, and development of PD patient and helper knowledge and confidence, especially at home after initial training. Patients described a trial-and-error iterative process of trying multiple strategies with input from multiple sources, which led to individualised solutions. CONCLUSIONS: The trial-and-error process may be crucial for maintaining PD. Individual patient success with PD may be promoted by creating expectations during training that a solution may require multiple attempts, and by a reimbursement policy that supports robust nursing support for safe progression through the trial-and-error process, particularly in the first few months for incident patients. Interventions to support patient motivation and optimal coping behaviour may also support an increase in PD modality duration for individual patients, and thus increase overall PD prevalence.


Asunto(s)
Fallo Renal Crónico , Diálisis Peritoneal , Peritonitis , Adulto , Humanos , Diálisis Peritoneal/efectos adversos , Calidad de Vida , Fallo Renal Crónico/terapia , Fallo Renal Crónico/complicaciones , Diálisis Renal/efectos adversos , Peritonitis/etiología , Catéteres/efectos adversos
2.
Facial Plast Surg Aesthet Med ; 25(5): 391-395, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36374237

RESUMEN

Introduction: Injectable hyaluronic acid (HA) fillers are commonly used to provide tissue augmentation and combat the effects of facial aging. Ovine and human recombinant formulations of the enzyme hyaluronidase (HAse) are used interchangeably; however, it is unknown if there exists a difference in their ability to degrade HA. Objective: To compare rates at which ovine and human recombinant forms of HAse degrade various HA fillers in vitro. Methods: Increasing amounts of either ovine or human recombinant HAse were added to fixed amounts of nine unique HA filler products. Degradation rates were then analyzed using a colorimetric method by measuring absorbance levels of degraded product. Results: Human recombinant HAse degraded more HA when compared with ovine HAse overall (p = 0.014, confidence interval [-0.015 to -0.0018]). Conclusions: Human recombinant HAse was found to be more effective on average in degrading HA fillers when compared with ovine HAse in vitro.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...